Proline Promag 10P
Electromagnetic flowmeter
The flowmeter for highest medium temperatures with a highly cost-effective transmitter
Promag P is the preferred sensor for applications with highest requirements in a multitude of industries. Combined with the Promag 10 transmitter for basic applications and direct integration, Promag 10P is dedicated for chemical and process applications with corrosive liquids and high medium temperatures. It will be the preferred solution for customers aiming for minimized cost of ownership. Promag 10P is available as compact or remote version.
-
Benefits
Versatile applications – wide variety of wetted materials
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
Cost-effective – designed for easy applications and direct integration
Safe...
-
Field of application
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
Device properties
Nominal diameter: max....
Documents / Manuals / Software
-
Proline Promag 10P
Technical Information
Electromagnetic flowmeter
Flow rate measurement in chemical or process applicationsTechnical Information (TI) -
Proline Promag 10
HART
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 10
Brief Operating Instructions
Electromagnetic flowmeter
Short Instruction (KA)11/17English -
Promag 10 to Proline Promag 50/53
Conversion Instructions
Conversion instructions of Promag 10 W/P/H compact or remote version to
Proline Promag 50/53 W/P/H compact or remote version.Conversion Instruction (UA) -
Repair kit cover remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65Mounting Instruction (EA) -
Replacing transmitter parts
Installation Instructions
Promag 10, Prosonic Flow 91 W
Mounting Instruction (EA) -
Replacing the transmitter
Installation Instructions
Promag 10, 23, 50, 53, 55
Mounting Instruction (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Mounting Instruction (EA) -
Replacing Sensor parts remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, Cubemass 8CN,
CNGmass 8DFMounting Instruction (EA) -
Interface parts
Installation Instructions
Promag 10, 23, 50, 51, 53, 55, 400, 800
Mounting Instruction (EA) -
Replacing cover and O-ring
Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73Mounting Instruction (EA) -
Change of device roots in CER database
Installation Instructions
Promag 30, 33, 10, 50, 53, Promass 60, 63, 80, 83, Prowirl 70, 77, 72,
73Mounting Instruction (EA) -
Installing ground disks
Installation Instructions
Promag, 10, 23, 50, 51, 53, 55, Promag 100, 200, 300, 800,
Promag 400 Index CMounting Instruction (EA) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promag 10, 23, 50, 51, 53, 55
Information on the PED
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Promag 10W, P
Zusatzinformation grosse Nennweiten
Supplementary info big nominal diameters
Zusatzinformationen zur Betriebsanleitung Promag 10: grosse Nennweiten,
Druckstufen
Supplementary information for Operating
Instructions Promag 10: big nominal diameters, nominal pressuresSpecial Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Information
NEMA 6P
Special Documentation
Proline Promag W, P
Special Documentation (SD) -
Proline Promag 10W, 50W, 53W
AS 4087 Flanschen/flanges
Special Documentation
Zusatzinformationen zu Messgeräten mit Flanschen gemäß der Australischen
Norm AS 4087.
Supplementary information for devices with
flanges according to the Australian AS 4087 standard.Special Documentation (SD) -
Proline Promag 10W/P
Sonderdokumentation
Special
documentation
Zusatzinformationen zu Messgeräten mit Flanschen gemäß der
Australischen Norm AS 2129.
Supplementary information for
deviceswith flanges according to the Australian AS 2129 standard.Special Documentation (SD) -
Proline Promag 10
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 10 HART: 1.03.00Manufacturer Information (MI) -
Proline Promag 10
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 10 HART: 1.04.00Manufacturer Information (MI) -
Proline Promag 10
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 10 HART: 1.02.00Manufacturer Information (MI) -
Flow measurement in utilities - for the US Market
Energy management in your hands - customized solutions for
compressed air, gas, steam and waterCompetence Brochure (CP)12/10English -
Modern measurement on filling machines
Filling, cleaning and sterilization
Competence Brochure (CP)07/10English -
A 15% cost saving in sludge dewatering by reducing flocculant dosage.
Dewatering of sludge is a process aimed at reducing its volume by
removing as much water as possible. Frequently this is done
mechanically, where the sediment is subjected to a so-called
conditioning
process; this involves changing the structure and properties of the
sediment, weakening the forces binding water to the surface of
particles.
A commonly used method of conditioning is a chemical method and
consists of adding electrolytes to the sludge, such as aluminum sulfate,
ferric sulfate or ferric chloride, or polyelectrolytes based on organic
polymers.Case Studies (CS)06/11English -
Promag 10P
Magnetisch-induktives Durchflussmessgerät, mikroprozessorgesteuert
und
überwacht in Kompakt-Bauweise (optional getrennt)Tender Text12/12German -
Promag 10 P
electromagnetic flowmeter, microprocessor controlled and monitored,
compact designTender Text03/10English -
DTM Single, Promag_10_V1_02_00, 06.07.2019 (Flow, Promag, 0x0045)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, Promag_10_V1_01_00, 06.07.2019 (Flow, Promag, 0x0045)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, Promag_10_V1_03_00, 06.07.2019 (Flow, Promag, 0x0045)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, Promag_10_V1_00_00___V1_00_02, 06.07.2019 (Flow, Promag, 0x0045)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-, O5P2B-
Declaration Number: HE_01038_02.18
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationGerman , English -
Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H, Promag P
Product Code: 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5RH-, 5SH-, DDA-, DK5G-, DK5HA-, DK5HB-, DKH-, O5H1B-, O5H2B-, O5P1B-, O5P2B-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5H-, 5DH-, 5CH-, 5BH-, 55S-, 55H-, 53P-, 53H-, 50P-, 50H-, 10P-, 10H-
Declaration Number: FDA_00131_03.17FDA DeclarationGerman , English -
Promag 10
Product Code: 10D-, 10E-, 10H-, 10L-, 10P-, 10W-
Declaration Number: EC_00289_01.16EU DeclarationGerman , English , fr -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-
Declaration Number: EC_00696_01.18EU DeclarationGerman , English -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: O5P1B-, 5P5B-, 5P3B-, 5P2B-, 5P1B-, 55S-, 53P-, 50P-, 10P-
Declaration Number: EC_00697_01.18EU DeclarationGerman , English -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 50W-, 50P-, 50E-, 10W-, 10P-, 10E-, 55S-, 53W-, 53P-, 53E-, 51W-, 51P-
Declaration Number: EC_00054_04.15EU DeclarationGerman , English , fr -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-
Declaration Number: EC_00696_02.18EU DeclarationGerman , English -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: O5P1B-, 5P5B-, 5P3B-, 5P2B-, 5P1B-, 55S-, 53P-, 50P-, 10P-
Declaration Number: EC_00697_02.18EU DeclarationGerman , English -
Promag 10
Product Code: 10P-, 10W-
Region/Country: Germany
Approval Agency: VdS
Approval Number: G 4080010MiscellaneousGerman -
Promag 10, Promag 50, Promag 51, Promag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 55H-, 55S-, 5D4C-, 5E1B-, 5H2B-, 5H3B-, 5L4B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4C-, 5W8B-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 53L-, 53P-, 53W-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H1B-, 5H2B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5W4B-, 5W4C-, 5W8B-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
Promag 10
Product Code: 10P-, 10W-
Region/Country: Germany
Approval Agency: VdS
Approval Number: G 4080010MiscellaneousGerman -
Promag 10
Product Code: 10D-, 10P-, 10H-, 10W-, 10L-, 10E-
Region/Country: Canada
Approval Agency: CSA
Category: I/2/A,B,C,D/, II,III/1/E,F,G/T6...T1
Protection: DIP, NIExplosion ProtectionEnglish -
Promag 10
Product Code: 10D-, 10E-, 10H-, 10L-, 10P-, 10W-
Region/Country: USA
Approval Agency: FM
Category: I/2/A,B,C,D/T6...T1, II,III/1/E,F,G/T6...T1
Protection: DIP, NIExplosion ProtectionEnglish -
Promag P, Promag W, Promag 53, Promag 50, Promag D, Promag 51, Promag 10, Promag L
Product Code: 5W8B-, 53P-, 53W-, 50P-, 50W-, 5P1B-, 5W4C-, 5P2B-, 50L-, 5D4C-, 50D-, 5P5B-, 5W5B-, 5W4B-, 51W-, 5P3B-, 5D4B-, 51P-, 10P-, 10W-, 10L-, 10D-, O5W1B-, O5P2B-, O5P1B-, 5L8B-, 5L4C-, 5L4B-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag P
Product Code: 10P-, 50P-, 51P-, 53P-, 5P1B-
Region/Country: France
Approval Agency: ACSHygienic Equipmentfr -
Promag 53, Promag 50, Promag 35, Promag 23, Promag 10
Product Code: 50W-, 53P-, 53W-, 53H-, 50P-, 50H-, 10P-, 10H-, 10W-, 23H-, 35S-, 23P-
Region/Country: PolandPressure EquipmentEnglish , Polish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 53H-, 53W-, 53P-, 50H-, 50P-, 50W-, 55S-, 55H-, 50D-, 53L-, 53E-, 50L-, 51W-, 51P-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 56810_1MetrologyRussian -
Promag 10, Promag 23, Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 55S-, 55H-, 53W-, 53P-, 53H-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50D-, 23P-, 23H-, 10W-, 10P-, 10L-, 10H-, 10D-
Region/Country: Kazakhstan
Approval Agency: MEMST
Approval Number: GOST-12129MetrologyRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian -
Promag 10, Promag P, Promag 53, Promag W, Promag H, Promag 50, Promag L, Promag 51, Promag 55, Promag D, Promag E
Product Code: 53P-, 53W-, 53H-, 50P-, 50W-, 5P1B-, 50H-, 55S-, 5H1B-, 5W4C-, 5L4C-, 5P2B-, 55H-, 53L-, 50L-, 5D4C-, 5H2B-, 5E1B-, 50D-, 53E-, 5W4B-, 51W-, 5L4B-, 5D4B-, 51P-, 10P-, 10W-, 10H-, 10L-, 50E-, 5W8B-, 10E-, 10D-
Region/Country: Belarus
Approval Agency: BELGIM
Approval Number: 9768MetrologyRussian -
Promag 10, Promag 23, Promag 50, Promag 51, Promag 53, Promag E, Promag 55, Promag H, Promag P, Promag W
Product Code: 10E-, 53E-, 53H-, 53L-, 53P-, 53W-, 55H-, 55S-, 5D4-, 5E1B-, 5H1B-, 5H2B-, 5L4-, 5W4-, 5P1B-, 5P2B-, 5W8B-, 10D-, 10H-, 10L-, 10P-, 10W-, 23H-, 23P-, 50D-, 50E-, 50H-, 50L-, 50P-, 50W-, 51P-, 51W-
Region/Country:
Approval Agency: AZSTAND
Approval Number: CH.S.29.999.Ü 001318Metrology
Accessories / Spare parts
-
-
Nr A Order code 50104751
Kit Main-PCB PMAG10 85-250VAC
-
Nr A Order code 50104752
Kit Main-PCB Promag 10,20-28VAC/11-40VDC
-
Nr A Order code 71098237
-
Nr A Order code 71098239
-
-
-
Nr 3 Order code 50104749
Kit 10 fuses 1.0 A/250 slow
-
Nr 3 Order code 50104750
Kit 10 fuses 1.6 A/250 slow
-
-
-
Nr B Order code 50104745
Kit display 10/91W with keyboard
-
-
-
Nr C Order code 50104754
Kit connec. board PMAG10 FS elect
-
Nr C Order code 71098240
-
-
-
Nr D Order code 50098018
-
Nr D Order code 71039497
Kit connection board D/E/L/P/S/W FS HE
Usage: 10/50/53/55 HE = harsh environment
-
-
-
Nr 1 Order code 50108138
Kit Terminal Block 10/1YH/91W
-
-
-
Nr 13 Order code 50094038
-
Nr 13 Order code 71247838
Repair kit cover, remote version
Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease
-
-
-
Nr 9 Order code 50094038
-
-
-
Nr 5 Order code 50104746
Kit cover 10/91W with window
-
-
-
Nr 6 Order code 50104747
Kit cover 10/1YH/91W blind version
-
-
-
Nr 10 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 10 Order code 50096840
Kit 10 cable glands M20x1,5
-
Nr 10 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 10 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
-
-
Nr 4 Order code 50104748
Kit PCB/Display carrier 10/91W
-
-
-
Nr 7 Order code 50104753
Kit housing gaskets Promag10/1YH housing
-
-
-
Nr 8 Order code 50097147
-
-
-
Nr 2 Order code 50099102
Kit Bushing to field/SS-housing
-
-
-
Nr 15 Order code 50098019
Kit parts housing FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W
-
-
-
Nr 12 Order code 50098020
Kit parts housing compact Stnd/HT
Usage: 10/23/50/51/53/55 Sensor: D/E/H/L/P/S/W
-
-
-
Nr 14 Order code 50098023
Kit housing gasket FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W
-
-
-
Nr 11 Order code 50098024
Kit housing gasket compact Stnd/HT
Usage: 10/23/50/51/53/55 Sensor: D/E/L/P/S/W
-
-
-
Order code 10XXX-
Promag 10, transmitter
-
Order code DK5CA-
Promag, cable remote version
10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable
-
Order code DK5WM-
-
Order code DK5GC-
-
Order code DK5GD-
Promag, grounding disc/protection disc
Includes 1 grounding disc/protection disc
-
Order code FXA193-
Serviceinterface FXA193
The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.
-