Specs at a glance
-
Accuracy
(Pt100, -50...200 °C) <= 0,2 K
(Pt100, -58...392 °F) <= 0,4 °F
Field of application
The transmitter is designed for the transformation of an RTD Pt100 sensor signal in a fixed measuring range. The standardized output signal used for process measurement is a 4 to 20 mA signal. This means fast, easy and cost-saving temperature measuring as well as reliable and precise measured values for for a wide range of industry applications. Installation is realized on DIN rail according to IEC 60715 (housing width: 22.5 mm).
Fixed range temperature transmitter for converting a Pt100 input signal into a scalable 4 to 20 mA analog output signal
Input: Resistance thermometer (RTD) Pt100
For DIN rail mounting
Benefits
High accuracy in complete ambient temperature range
Fault signal on sensor break or short circuit, NAMUR NE 43 compliant
EMC as per NAMUR NE 21, CE
Ex-Certification: ATEX Ex ia, FM IS, CSA IS
UL recognized component to UL 3111-1
Ship building approval GL
Galvanic isolation
Fundamental selection
-
Simple products
- Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Technical information Temperature Transmitter iTEMP® Pt100 TMT127
Temperature Transmitter for Pt100
EN 17/06/200501/03/2004Language:
English
Version:
17/06/2005
File size:
829.1 KB
File name:
Ti095ren.pdf
-
-
-
Short Instruction (KA)
Brief operating instructions
Temperature transmitter DIN rail iTEMP® RTD TMT127, TC TMT128
EN 25/08/200605/08/2004Language:
English
Version:
25/08/2006
File size:
860.1 KB
File name:
Ka140ra3.pdf
-
-
-
Ex Safety Instruction (XA)
iTEMP TMT121, TMT127, TMT128 ATEX: II2 (1)G: Ex ia [ia Ga] IIC T4... T6 Gb Safety Instructions
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.EN 01/08/201627/04/201202/11/2005Language:
English
Version:
01/08/2016
File size:
860.7 KB
File name:
XA00013RA3_1416.pdf
-
-
-
Ex Safety Instruction (XA)
XA iTEMP TMT121/127/128, TMT112, TMT122
ATEX:
Ex nA IIC GcEN 13/03/202315/06/201605/05/201501/02/2002Language:
English
Version:
13/03/2023
File size:
396.9 KB
File name:
XA00018REN_1523-00.pdf
-
-
-
Certificates FM/CSA (ZD)
Control Drawing CSA iTEMP TMT121, TMT127, TMT128
Temperature transmitter iTEMP TMT121, TMT127, TMT128
Installation Notes for hazardous locationsLanguage:
English
Version:
20/10/2015
File size:
208.5 KB
File name:
141001112A.pdf
-
-
-
Manufacturer Declaration
Product family: Accessories, Configuration Kit, DIN rail transmitter, Field transmitter, Head transmitters
Product root: TID10-, TMT127-, TMT128-, TMT142B-, TMT162-, TMT182B-, TMT188-, TMT31-, TMT36-, TMT71-, TMT72-, TMT80-, TMT82-, TMT84-
, TMT85-, TMT86-, TXU10-
Declaration number: HE_02282_01.25
Manufacturer specification: RoHS
Additional information: China RoHSEN 27/11/2025Language:
English
Version:
27/11/2025
File size:
284.8 KB
File name:
HE_02282_01.25.pdf
-
-
-
EU Declaration
Product family: DIN rail transmitter
Product root: TMT121-, TMT127-, TMT128-
Declaration number: EC_00161_02.16EN 01/07/2021Language:
English
Version:
01/07/2021
File size:
165.4 KB
File name:
EC_00161_02.16.pdf
-
-
-
EU Declaration
Product family: DIN rail transmitter
Product root: TMT112-, TMT121-, TMT122-, TMT127-, TMT128-
Declaration number: EC_00162_02.16EN 01/07/2021Language:
English
Version:
01/07/2021
File size:
165.3 KB
File name:
EC_00162_02.16.pdf
-
-
-
EU Declaration
Product family: DIN rail transmitter
Product root: TMT121-, TMT127-, TMT128-
Declaration number: EC_00322_01.16EN 20/04/2016Language:
English
Version:
20/04/2016
File size:
871.2 KB
File name:
EC_00322_01.16.pdf
-
-
-
Explosion Protection
Product family: DIN rail transmitter, Field transmitter, Head transmitters
Product root: TMT127-, TMT128-, TMT142B-, TMT162-, TMT182B-, TMT188-, TMT71-, TMT72-, TMT82-, TMT84-, TMT85-, TMT86-
Region: Eurasian Economic Union
Approval agency: T-Standard
Protection: Ex d Zone 1, Ex i Zone 0, Ex i Zone 1, Ex t Zone 21Language:
Unknown
Version:
02/08/2024
File size:
3.6 MB
File name:
EAC KZ 7500525.01.01.01840.pdf
-